Encoders
Blog
Home
About Nidec-Avtron
Careers
News, Events & Updates
Login
Do you need an Encoder
Find an Encoder
By Style
Light Mill Duty
Mill Duty
Heavy Mill Duty
Severe Mill Duty
Hazardous Duty
OEM Modules
Absolute
By Environment
By Motor Type
By Application
Crane & Hoist
Machinery
Metals
Marine
Oil & Gas
Pulp & Paper
Wind Power
Wood
Competitive Cross Reference
Configure Encoder
Replace an Avtron Encoder
Accessories
Browse Encoders
Overview
How To Order
Overview
Search Reps and Distributors
Search Integrators
Emergency Orders
Place Your Order
Price A Part Number
Terms and Conditions
Already have an Encoder
Knowledge Base
Overview
Encoders vs. Resolvers
Incremental vs. Absolute
FAQs
Case Studies & White Papers
Glossary
2D & 3D Drawings
Mounting Styles
Optical v Magnetic
Encoder Product Literature
Support
Overview
Repair/Return
Discontinued Encoder Models
Manuals
Installation Videos
Onsite Help
Overview
Request Equipment Evaluation
Request Onsite Engineer
Encoder Lunch & Learn
24 Hour Emergency Dispatch
Contact Avtron
Contact Us
Overview
Create an Account
Find Distributors/Sales Representatives
Browse Encoders
Configure
Quick-Quote
JavaScript must be supported by the browser and enabled for this page to work.
Configurator v2
Save
Load
Reset
Print Preview
Recalculate
Zoom
10%
25%
50%
60%
70%
80%
90%
100%
125%
150%
Help
Expert
Cross Reference
Quote
OEM
AV5
AV6A
AV6M
AV12
AV20
AV25
AV30
AV45
AV56
AV56S
AV67
AV85
AV115
AV125
AV485
AV685
AV850
AVSK
BEI HS35
Dyn HS35
HS6A
HS6M
HS25A
HS35A
HS35M
HS40
HS45
KXL
KXS
K661
M3
M3-1 M3-2
M4
M4-1 M4-2
M6
M6C
M7
M56 67 85 115
M185
M19x
M285
M460
M484
M485
M628A
M685
M785
M925
RIM1250
RT1
RIM6200
RT6
RIM8500
RT8
Slim-Line
XR5
XR12
XR4F
XR45
XR47
XR56
XR67
XR85
XR97
XR115
XR125
XR485
XR685
XR850
XRB1
XRB2
XT45
Parts
Style|Family
Application
Environment
Motor
Multipliers
Repairs
Encoder Type
Temperature Range
Mounting Style
Shaft Style
Left Output Voltage
Left Output PPR
Right Output Voltage
Right Output PPR
Accessories:
Connector Style
Special Options
Go to Quote Page
Mating Cable
Mating Cable Length
3D & 2D Model Downloads Available!
Key to Delivery Codes Above
+
Stock Assembly, fastest delivery
‡
Some non-stock parts, may extend lead time
!
If present, indicates an error that must be corrected
Select Encoder Model
AV485 Severe Mill Duty Solid Shaft Magnetic Encoder
N= -20°C to +80°C
C= -40°C to +80°C
H= -20°C to +120°C (NOTE: Requires instrument air flow)
X= Standard NEMA 56C Face Mount (No Foot Mount Included)
1= Standard Bolt Pattern Foot Mount Bracket (Avtron & RIM6200/H56)
2= BC42/46 Bolt Pattern Foot Mount Bracket (GE Analog Tachogenerator)
Future
Future
Future
Future
S= Standard Single-Ended 5/8"x2" Shaft
D= Dual Shaft
G= Shaft Grounding Option with Standard Single Shaft
O= Overspeed Switch (See Special Option Code 6xx)
Future
Future
Future
Future
Future
X= No Left Output
8= 5-24v in, 5-15v out hi-power standard (4125)
9= 5-24v, 5v fixed out (7272)
6= 5-24v in, 5-24v out (7272) recommended for single-ended wiring (A,B,Z, no A/,B/,Z/)
Future
Future
Future
Future
X= No Left Output
F= 60 PPR
G= 100 PPR
H= 120 PPR
A= 128 PPR
L= 240 PPR
N= 256 PPR
P= 300 PPR
E= 360 PPR
B= 480 PPR
Q= 500 PPR
R= 512 PPR
S= 600 PPR
J= 960 PPR
W= 1000 PPR
Y= 1024 PPR
Z= 1200 PPR
6= 1800 PPR
3= 2000 PPR
4= 2048 PPR
5= 2500 PPR
D= 4096 PPR
8= 4800 PPR
9= 5000 PPR
0= Special PPR
X= No Right Output
8= 5-24v in, 5-15v out hi-power standard (4125)
9= 5-24v, 5v fixed out (7272)
6= 5-24v in, 5-24v out (7272) recommended for single-ended wiring (A,B,Z, no A/,B/,Z/)
Future
Future
Future
Future
X= No Right Output
F= 60 PPR
G= 100 PPR
H= 120 PPR
A= 128 PPR
L= 240 PPR
N= 256 PPR
P= 300 PPR
E= 360 PPR
B= 480 PPR
Q= 500 PPR
R= 512 PPR
S= 600 PPR
J= 960 PPR
W= 1000 PPR
Y= 1024 PPR
Z= 1200 PPR
6= 1800 PPR
3= 2000 PPR
4= 2048 PPR
5= 2500 PPR
D= 4096 PPR
8= 4800 PPR
9= 5000 PPR
0= Special PPR
A= 10 pin MS style w/o Mating Plug
B= 10 pin MS style w/Plug
C= 10 pin MS style w/Plug & Flex Cond. Adapt.
E= M737A Pinout 5 pin MS, w/o Plug
F= M737A Pinout 5 pin MS style with Plug
G= Industrial EPIC Style w/Lakeshore Pinout
H= M727A Pinout 5 pin MS, w/o Plug
J= M727A Pinout 5 pin MS, with Plug
K= Condulet with leads
L= 10 pin MS style w/90° Plug
N= 5 ft [1.5m] Flex Conduit, Leads Only
P= Industrial EPIC Style w/Plug
R= Baldor Mini MS style w/Plug
S= Baldor Mini MS style on 3' Cable w/Plug
T= 5 ft [1.5m] Flex Conduit w/Terminal Box
V= Industrial EPIC Style w/Plug w/Insulated Adapter
W= 3' Sealed Cable w/Leads, No Connector
X= No connector (no sensor, housing only)
Y= 5 ft [1.5m] Flex Conduit w/Terminal Box w/ins. Adapter
Z= Industrial EPIC Style on 3' Cable with Plug
1= Industrial Mini-EPIC Style w/Plug (replaces M3/M4)
3= 6 Pin MS style w/Plug, M940 pinout
Future
Future
Future
Future
None
391372 Separate cable only, no connectors, 10 conductor, w/overall shield (100ft max)
B33276 10 Pin MS style Plug w/cable attached for HS45 & Large Encoder Pinout
A33822 10 Pin Small EPIC Style Industrial Plug w/cable attached for SMARTach Options 1, Q
A38467 Industrial EPIC Style Mating Plug "P", "G", "Z" to leads, 10 Cond.
A30783 8 in./200mm Wiring Extension Kit, MS style 10 pin plug to 10 pin jack (option C)
A30784 8 in./200mm Wiring Extension Kit, MS style 5 pin jack to MS style 5 pin plug, 4 conductor (options E, F, H, J)
B20835 SMARTach Wiring Kit MS style 10 pin to Terminal Box, 6 conductor (A, A/, B, B/, no marker) (Option C)
B23873 SMARTach Wiring Kit MS10 pin to Terminal Box, 10 Cond. (A, A/, B, B/, Z, Z/) (Option C)
B25025 6 ft/1.8m Flex. Conduit, MS style 10 pin plug to MS style 10 pin jack
B29506 8ft/2.4m Flex. Conduit, Industrial (EPIC) Connector to Terminal Box
B29916 8ft/2.4m Flex. Conduit, Industrial (EPIC) Connector to Terminal Box with MS style connector tap for tester
Future
Future
Future
Future
Future
None
1ft/0.3m
2ft/0.6m
3ft/0.9m
5ft/1.5m
10ft/3m
15ft/4.5m
20ft/6m
25ft/7.5m
30ft/9m
33ft/10m
50ft/15m
60ft/18m
75ft/22.5m
99ft/30m
100ft/30.5m
250ft/76m
500ft/152m
000= None
002= (Obsolete see 4xx option codes below)
003= Analog Brushless Converter (K661) Package Included
004= Super Magnetic Shielded Sensor(s)
401= 1270 (Special) Output PPR, (Set PPR Code(s) = 0)
402= 150 (Special) Output PPR, (Set PPR Code(s) = 0)
403= 50 (Special) Output PPR, No Right Output (Set PPR Codes = 0)
404= 16 PPR (Special) Right Output (Set Right PPR Code Only = 0)
405= 16 (Special) Output PPR (Set PPR Code(s) = 0)
406= 6000 (Special) Output PPR (Set PPR Code(s) = 0)
407= 2800 (Special) Output PPR (Set PPR Code(s) = 0)
408= 1400 (Special) Output PPR (Set PPR Code(s) = 0)
409= 30 (Special) Output PPR (Set PPR Code(s) = 0)
601= Mechanical overspeed, 1200 RPM, 1 NO & 1 NC Contacts, 5-13mm dia. Cable
602= Mechanical overspeed, 2700 RPM, 1 NO & 1 NC Contacts, 5-13mm dia. Cable
603= Mechanical overspeed, 720 RPM, 1 NO & 1 NC Contacts, 5-13mm dia. Cable
604= Mechanical overspeed, 900 RPM, 1 NO & 1 NC Contacts, 5-13mm dia. Cable
605= Mechanical overspeed, 2400 RPM, 1 NO & 1 NC Contacts, 5-13mm dia. Cable
901= Special 1'/0.3m cable length built into sensor
902= Special 2'/0.6m cable length built into sensor
903= Special 3'/0.9m cable length built into sensor
905= Special 5'/1.5m cable length built into sensor
910= Special 10'/3m cable length built into sensor
915= Special 15'/4.5m cable length built into sensor
920= Special 20'/6m cable length built into sensor
925= Special 25'/7.5m cable length built into sensor
930= Special 30'/9m cable length built into sensor
933= Special 33'/10m cable length built into sensor
Future
Future
Future
Future