Avtron XRB2 Intrinsic Safety Isolator

Avtron XRB2 Intrinsic Safety Isolator

Avtron XRB2 Intrinsic Safety Isolator

  • Obsolete, replaced by XRB3
  • 3 Year No-Hassle Warranty
Outline Drawing
XRB2 Isolators are fully replaced by XRB3 Isolators for all applications.
Operating Power: 12-24VDC, nom. 200mA (w/SMARTSafe™ encoder); max 440mA
Output Voltage:  12-24V, nom.
Output Format: Incremental A Quad B with marker (A,A–, B,B–, Z,Z– quadrature)
Frequency Range: 0 to 165 KHz
Maximum Cable Length: 1000' [300m] XRB2 to control; 500' [152m] XRB2 to encoder*
Temperature: -40°C to 80°C (Storage -40°C to 100°C)
Environmental: IP54, cabinet mount
Vibration: 5-2000Hz, 18Gs
Weight: 1.1 lbs. [0.5 kg]

*XRB2 to encoder allowable cable length may be affected by cable characteristics and gas group application.

Certifications
     Associated apparatus for installation in Unclassified locations.
     Provides intrinsically safe circuits for use in metals, marine, and oil & gas applications
     cULus Class I, Division 1 Listed, (Gas) Groups A, B, C, D
     cULus Class I, Zone 0, Group IIC Listed [AEx ia Ga] IIC

      ATEX/IECEx, Zone 1, Group IIC [Ex ia IIC Gb] [Ex ia IIC Db]
   
  • Provides Level 1 Encoder Protection
  • Obsolete, replaced by XRB3
Industry General Food & Beverage Pulp & Paper Wood Products Wind Power Crane & Hoist Metals Mining Marine Oil & Gas

Light Mill Duty

AV20, AV25, AV32, AV4, AV4/HS4 Configuration Tool, AV6A, AV6M, HS25A, HS35A, HS4, HS6A, K661, SC65
                   

Mill Duty

AV32, HS35M, HS6M, K661, M185, M3, M3(small), RAHS35M
                   

Heavy Mill Duty

AV115, AV125, AV44, AV45, AV5, AV56, AV56S, AV67, AV85, AV850, AVSK, Carlen Replacement, HS44, HS45, K661, M4, M4(small), XP5, XR115, XR12, XR125, XR45, XR4F, XR5, XR56, XR67, XR85, XR850, XR97, XRB1, XRB2, XRB3
                   

Severe Mill Duty

AV12, AV30, AV485, AV5, AV685, Carlen Replacement, HS40, K661, M484, M6, M6C, M7, XP5, XPH1, XPH8, XR12, XR485, XR5, XR685, XR97, XRB1, XRB2, XRB3,
                   
The XRB2 allows the replacement of competitive encoder systems including:

Baumer Hubner:
EEx HOG 161, HOG8, HOG9, HOG10, HOG11, HOG131, HOG161, HOG163, HOG165 encoders

BEI:
HS35, HS35F, H37, H38, H40, L25 encoders

924-08062-001, 924-08062-002, 924-08062-003, 924-08063-001,
924-08063-002, 924-08064-001, 924-08064-002, 924-08172-001,
924-08172-002, 924-08173-001, 924-08173-002, 924-08174-001,
924-08174-002, EM-DR1-IS-5-RTB-24V/V, EM-DR1-IS-5-RTB-24V/4,
EM-DR1-IS-5-RTB-24V/OC intrinsic safety barriers & systems

BEI Ideacod encoders:
GAMX, GAUX, IHM5, IHO5, IHM9, NAMX

Dynapar encoders:
X25 encoder

NorthStar Encoders
EN42, EN44

Pepperl+Fuchs
RSI 58X-,RVI 58X-, RVI84, 14-1436X, 14-14361, 14-14366

And many other hazardous area, intrinsically safe and explosion proof ATEX, IECEx, UL, and cUL rated encoders and systems. 

Related Products

Adobe Reader

In This Section

  • ATEX

    ATEX is a directive used worldwide for equipment, including encoders, to be used around or in explosive atmospheres. ATEX certified equipment is NOT necessarily interchangeable with US-based UL Class/Division or Class/Zone rated equipment, nor IECEx rated equipment. ATEX is an alternative and different system. Review our full line of Avtron Explosion Protected, ATEX certified encoders, including M6, M6C and XR models.

  • Encoder

    A device which indicates position and speed via a set of digital outputs. Incremental encoders output quadrature (A Quad B) signals, and may add a marker pulse once per revolution.  Absolute encoders typically indicate position via a digital message, a set of parallel outputs, or analog values.

  • Explosion Protected

    Also known as Flameproof, explosion protected equipment has additional protection/safety enhancements for use in explosive atmospheres. Explosion Protected devices maybe placed directly into hazardous areas within their nameplate rating. No additional equipment is required if installation instructions are followed properly. By comparison, Intrinsically Safe devices may require the use of additional, external protection/current limiting devices outside of the hazardous area. Avtron offers hollow shaft M6C Explosion Protected encoders.

  • IECEx

    IECEx is a directive used worldwide for equipment, including encoders, to be used around or in explosive atmospheres. IECEx certified equipment is NOT necessarily interchangeable with US-based UL Class/Division rated equipment, or ATEX rated equipment. IECEx is an alternative and different system. Avtron offers a full famliy of Explosion Protected, IECEx certified XR encoders, and M6C is also IECEx certified.

  • Incremental Encoder

    An encoder that produces pulses in proportion to distance moved or rotated. Incremental encoders can also have a marker pulse Z, Z NOT (, ) once per revolution to provide a position reference. Avtron produces a full range of incremental rotary encoders.

  • UL Listed

    UL Listed Avtron encoders can be directly applied to any hazardous duty application which requires Class and Division, Class and Zone or AEX certification.  Note that UL Listing is a different system than ATEX or IECEx.  Ensure the model you select has the UL listing which meets the application requirements.

Contact Avtron