For Level 2 applications requiring ATEX/IECEx Zone 2 or 22 or cULus Class I, Division 2, Groups A,B,C,D use the XR97 directly in your application, with no barrier, isolator or cable gland required.
For Level 1 applications requiring ATEX/IECEx Zone 1 or 21 protection use the XRB1 or XRB2 isolator in your control cabinet which permits the use of intrinsically safe wiring instead of explosion-proof conduit or glands. The XR56 can also be used in UL Class I Div 1 & Zone 0 applications using the XRB2 Isolator.
Unlike the competition, Avtron SMARTSafe encoder systems are protected against short circuits, power-to-output wiring, and output-to-ground faults.
Instead of mounting a tiny optical encoder with weak bearings on a wobbling stub shaft, mount XR97 directly on your machine and install the rotor on your main application shaft. Vibration, shock, liquids, dust and dirt won't harm SMARTSafe encoders! Paint booths, top drives, draw works, coil tubing rigs...XR97 can keep them all working 24-7-365.
Eliminate the biggest cause of encoder failure--eliminate the bearings with XR97 hazardous duty encoder sensors.
Operating Power: (add load and cable drive current as req'd)
Level 1 (XRB1): 12-24VDC In, 10.6V Out, 150 mA
Level 1 (XRB2): 12-24VDC In/Out, 150 mA
Level 2 Protection: 5-24VDC In/Out, 150mA
Output Format: A Quad B with marker (A,A\; B,B\; Z,Z\)
Frequency Range: 0 to 165 KHz
PPR: 8-6000
Speed: 5000 RPM
Maximum Cable Length:
Level 1: Encoder 500' Isolator 1000'
Level 2 (5 to 12 VDC in) 500'
Level 2 (15 to 24 VDC in) 250'
Rotor Position: +/- 0.100” [+/- 2.54mm].
Sensor Rotor Gap: 0.04", +0.015"1-0.030" [1.02mm +0.381-0.76mm]
Temperature: -40°C to 80°C (storage -40°C to 100°C)
Environmental: IP54 (see manual for details)
Vibration: 5-2000Hz, 20G, 100G Shock
Weight: 2.2lbs [1kg]
Certifications:
Level 1: ATEX/IECEx Zone 1 & 21 Group IIC
Level 1: cULus Class I Div 1 and Zone 0 Group A,B,C,D*
Level 2: ATEX/IECEx Zone 2 & 22 Group IIC
Level 2: cULus Class I Div. 2 Groups A,B,C,D
*See installation drawings for Warnings and Limitations.
- Sensor PPR can be factory reprogrammed
- Full protection against short circuits, reverse voltage, phase-to-phase shorts
- Shrugs off dirt, oil, and water contamination
- No glass disks to break or optics to fail
- 4,500,000+ hour MTBF design
- Full protection against short circuits, reverse voltage, phase-to-phase shorts
- Direct Machine-Mount
- Self-Diagnostic LED and Alarm Output
Industry | Mining | General | Wind Power | Pulp & Paper | Oil & Gas | Marine | Metals | Machinery | Crane & Hoist |
---|---|---|---|---|---|---|---|---|---|
Light Mill DutyHS4 Encoder Programming Tool Cables and Connectors Encoder Couplings Rush AV4 AV25 HS25A AV6A HS6A K661 AV6M AV4 HS35A AV20 |
|
||||||||
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
-
ATEX EC-Type Certificate XR Zone 1
-
ATEX EC-Type Certificate XR Zone 2
-
IECEx Zone 1&21 Certificate of Conformity XR Models
-
IECEx Zone 2&22 Certificate of Conformity XR Models
-
Nidec-Avtron Terms and Conditions
-
Nidec Industrial Solutions ISO Certificate
-
IECEx Zone 1&21, Zone 2&22 Cert. XR Models
-
Class 1, Div 1 Class 1, Zone 0 Cert. XR Encoders
-
Class 1, Div 2 Groups ABCD Cert. XR Encoders UL Listed
-
Class 1, Div 2 Groups ABCD Cert. XR Encoders UL Recognized
No Related Materials Available
Compititive Products
-
XR97 SMARTSafe™ encoder sensors can be used to replace many competitive models including:
BEI:
H20, H25, H38, H40 encoders
HS35, H37, H38, H40, L25 explosion proof and intrinsically safe encoders
924-08062-001, 924-08062-002, 924-08062-003, 924-08063-001,
924-08063-002, 924-08064-001, 924-08064-002, 924-08172-001,
924-08172-002, 924-08173-001, 924-08173-002, 924-08174-001,
924-08174-002, EM-DR1-IS-5-RTB-24V/V, EM-DR1-IS-5-RTB-24V/4,
EM-DR1-IS-5-RTB-24V/OC intrinsic safety barriers & systems
Baumer Hubner:
EEx OG 9, FOG 9, POG 9, POG 9 G, POG 90, POG 10, POG 10 G, POG 11, POG 11 G
EEx HOG 161, HOG8, HOG9, HOG10, HOG11, HOG131, HOG161, HOG163, HOG165 encoders
BEI Ideacod encoders:
GAMX, GEMX IHM5, IHM9, NAMX
Dynapar encoders:
X25 encoder
Pepperl+Fuchs:
RSI 58X-,RVI 58X-, RVI84, 14-1436X, 14-14361, 14-14366