Product Details

XRB1

Avtron XRB1 Intrinsic Safety Isolator

  • 3 Year No-Hassle Warranty
  • Obsolete, replaced by XRB2
XRB1 Isolators provided electrical isolation for XR encoders.
XRB1 Isolators are fully replaced by XRB2 Isolators for all applications.

Operating Power: 12-24V, nom. 150mA (w/SMARTSafe™ encoder); max 440mA

Output Voltage: 10.6V nom.

Output Format: Incremental A Quad B with marker (A,A–, B,B–, Z,Z– quadrature)

Frequency Range: 0 to 165 KHz

Maximum Cable Length: 1000' [300m] XRB1 to control; 500' [120m] XRB1 to encoder

Temperature: -40°C to 80°C (Storage -40°C to 100°C)

Environmental: IP54, cabinet mount

Vibration: 5-2000Hz, 18Gs

Weight: 1.1 lbs. [0.5 kg]


Certifications: CE 0539 Ex [II 2 GD]

    ATEX/IECEx Zone 1: Group II, Category 2, Gas Group IIC; [Ex ib IIC Gb]

    ATEX/IECEx Zone 21: Group II, Category 2, Dust Group IIIC; [Ex ib IIIC Db]

  • Provides Level 1 Encoder Protection
  • Obsolete, replaced by XRB2

No Related Materials Available

Compititive Products

  • The XRB1 allows the replacement of competitive encoder systems including:


    Baumer Hubner:

    EEx HOG 161, HOG8, HOG9, HOG10, HOG11, HOG131, HOG161, HOG163, HOG165 encoders


    BEI:

    HS35, HS35F, H37, H38, H40, L25 encoders

    924-08062-001, 924-08062-002, 924-08062-003, 924-08063-001, 924-08063-002, 924-08064-001, 924-08064-002, 924-08172-001, 924-08172-002, 924-08173-001, 924-08173-002, 924-08174-001, 924-08174-002, EM-DR1-IS-5-RTB-24V/V, EM-DR1-IS-5-RTB-24V/4, EM-DR1-IS-5-RTB-24V/OC intrinsic safety barriers & systems


    BEI Ideacod encoders:

    GAMX, GAUX, IHM5, IHO5, IHM9, NAMX


    Dynapar encoders:

    X25 encoder


    Pepperl+Fuchs

    RSI 58X-,RVI 58X-, RVI84, 14-1436X, 14-14361, 14-14366


    And many other hazardous area, intrinsically safe ATEX and IECEx rated encoders and systems. 

Related Products

Rating & review

See all reviews