Product Details

XRB2

Avtron XRB2 Intrinsic Safety Isolator

  • Obsolete, replaced by XRB3
  • 3 Year No-Hassle Warranty
XRB2 Isolators are fully replaced by XRB3 Isolators for all applications.

Operating Power: 12-24VDC, nom. 200mA (w/SMARTSafe™ encoder); max 440mA

Output Voltage: 12-24V, nom.

Output Format: Incremental A Quad B with marker (A,A–, B,B–, Z,Z– quadrature)

Frequency Range: 0 to 165 KHz

Maximum Cable Length: 1000' [300m] XRB2 to control; 500' [152m] XRB2 to encoder*

Temperature: -40°C to 80°C (Storage -40°C to 100°C)

Environmental: IP54, cabinet mount

Vibration: 5-2000Hz, 18Gs

Weight: 1.1 lbs. [0.5 kg]


*XRB2 to encoder allowable cable length may be affected by cable characteristics and gas group application.

Certifications

     Associated apparatus for installation in Unclassified locations.

    Provides intrinsically safe circuits for use in metals, marine, and oil & gas applications

   cULus Class I, Division 1 Listed, (Gas) Groups A, B, C, D

   cULus Class I, Zone 0, Group IIC Listed [AEx ia Ga] IIC

   ATEX/IECEx, Zone 1, Group IIC [Ex ia IIC Gb] [Ex ia IIC Db]

  • Provides Level 1 Encoder Protection
  • Obsolete, replaced by XRB3

No Related Materials Available

Compititive Products

  • The XRB2 allows the replacement of competitive encoder systems including:


    Baumer Hubner:

    EEx HOG 161, HOG8, HOG9, HOG10, HOG11, HOG131, HOG161, HOG163, HOG165 encoders


    BEI:

    HS35, HS35F, H37, H38, H40, L25 encoders


    924-08062-001, 924-08062-002, 924-08062-003, 924-08063-001,

    924-08063-002, 924-08064-001, 924-08064-002, 924-08172-001,

    924-08172-002, 924-08173-001, 924-08173-002, 924-08174-001,

    924-08174-002, EM-DR1-IS-5-RTB-24V/V, EM-DR1-IS-5-RTB-24V/4,

    EM-DR1-IS-5-RTB-24V/OC intrinsic safety barriers & systems


    BEI Ideacod encoders:

    GAMX, GAUX, IHM5, IHO5, IHM9, NAMX


    Dynapar encoders:

    X25 encoder


    NorthStar Encoders

    EN42, EN44


    Pepperl+Fuchs

    RSI 58X-,RVI 58X-, RVI84, 14-1436X, 14-14361, 14-14366


    And many other hazardous area, intrinsically safe and explosion proof ATEX, IECEx, UL, and cUL rated encoders and systems. 

Related Products