Operating Power: 12-24VDC, nom. 200mA (w/SMARTSafe encoder); max 440mA
Output Voltage: 12-24V, nom.
Output Format: Incremental A Quad B with marker (A,A, B,B, Z,Z quadrature)
Frequency Range: 0 to 165 KHz
Maximum Cable Length: 1000' [300m] XRB2 to control; 500' [152m] XRB2 to encoder*
Temperature: -40°C to 80°C (Storage -40°C to 100°C)
Environmental: IP54, cabinet mount
Vibration: 5-2000Hz, 18Gs
Weight: 1.1 lbs. [0.5 kg]
*XRB2 to encoder allowable cable length may be affected by cable characteristics and gas group application.
Certifications:
Associated apparatus for installation in Unclassified locations.
Provides intrinsically safe circuits for use in metals, marine, and oil & gas applications
cULus Class I, Division 1 Listed, (Gas) Groups A, B, C, D
cULus Class I, Zone 0, Group IIC Listed [AEx ia Ga] IIC
ATEX/IECEx, Zone 1, Group IIC [Ex ia IIC Gb] [Ex ia IIC Db]
- Provides Level 1 Encoder Protection
- Obsolete, replaced by XRB3
Industry | Mining | General | Wind Power | Pulp & Paper | Oil & Gas | Marine | Metals | Machinery | Crane & Hoist |
---|---|---|---|---|---|---|---|---|---|
Light Mill DutyHS4 Encoder Programming Tool Cables and Connectors Encoder Couplings Rush AV4 AV25 HS25A AV6A HS6A K661 AV6M AV4 HS35A AV20 |
|
||||||||
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
-
PQAN ATEX Cert.
-
ATEX EC-Type Certificate XR Zone 1
-
IECEx Zone 1&21 Certificate of Conformity XR Models
-
UL Class I, Div 1, Class I, Zone 0 Certification for XRB2 Isolator
-
Nidec-Avtron Terms and Conditions
-
XRB Isolator Enclosure Application Note (XRB1 & XRB2)
-
EU (ATEX) Dec of Conform 011712 XR Models Rev 4
-
Nidec Industrial Solutions ISO Certificate
-
IECEx Quality Assessment Report (QAR 12.0002/10)
-
PQAN ATEX Cert. Old
No Related Materials Available
Compititive Products
-
The XRB2 allows the replacement of competitive encoder systems including:
Baumer Hubner:
EEx HOG 161, HOG8, HOG9, HOG10, HOG11, HOG131, HOG161, HOG163, HOG165 encoders
BEI:
HS35, HS35F, H37, H38, H40, L25 encoders
924-08062-001, 924-08062-002, 924-08062-003, 924-08063-001,
924-08063-002, 924-08064-001, 924-08064-002, 924-08172-001,
924-08172-002, 924-08173-001, 924-08173-002, 924-08174-001,
924-08174-002, EM-DR1-IS-5-RTB-24V/V, EM-DR1-IS-5-RTB-24V/4,
EM-DR1-IS-5-RTB-24V/OC intrinsic safety barriers & systems
BEI Ideacod encoders:
GAMX, GAUX, IHM5, IHO5, IHM9, NAMX
Dynapar encoders:
X25 encoder
NorthStar Encoders
EN42, EN44
Pepperl+Fuchs
RSI 58X-,RVI 58X-, RVI84, 14-1436X, 14-14361, 14-14366
And many other hazardous area, intrinsically safe and explosion proof ATEX, IECEx, UL, and cUL rated encoders and systems.